904 resultados para Remoção de algas


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nessa pesquisa são relatados os resultados da determinação das concentrações de microcistina e de biomassa algal após as várias etapas de tratamento de amostras de água coletadas junto ao reservatório de Barra Bonita-SP visando obtenção de água potável. O tratamento foi realizado em escala de laboratório com e sem aplicação de carvão ativado em pó (CAP) e as etapas foram: coagulação com aplicação de cloreto férrico, sedimentação, filtração em papel de filtro. Foi possível observar que a pré-clarificação desse tipo de água por coagulação seguida de sedimentação requereu dosagens relativamente elevadas de cloreto férrico (80 mg/L), tendo sido verificada eficiência muito baixa de remoção de microcistina nas etapas de tratamento por sedimentação seguida de filtração, quando não foi aplicado CAP. Apenas com a aplicação de CAP a microcistina foi reduzida à níveis que atendessem os padrões de potabilidade previstos na Portaria 518/04 (concentração menor que 1 μg/L). A determinação de microcistina pelo método que utiliza Imunoadsorventes Ligados à Enzima (ELISA) mostrou-se uma ferramenta útil e confiável para detectar e quantificar essa toxina, embora ainda apresente custo relativamente elevado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Florações de cianobactérias nocivas ocorrem frequentemente em reservatórios brasileiros, devido ao incremento de nutrientes pela eutrofização e pelas mudanças climáticas, como o aquecimento global. Estas florações alteram a qualidade dos corpos hídricos, produzindo compostos de gosto e odor e cianotoxinas, que representam um problema para as Estações de Tratamento de Água (ETAs). Estes compostos, quando dissolvidos na água dificultam os tratamentos convencionais. Além das cianobacérias, um dinoflagelado exótico tem ocorrido em águas doces brasileiras, incluindo reservatórios utilizados para o abastecimento público. Os reservatórios de Caxias do Sul (RS – Brasil) são gerenciados pelo Serviço Autônomo Municipal de Água e Esgoto (SAMAE) e apresentam um histórico de florações de cianobactérias nocivas, como Dolichospermum Bory de Saint-Vincent ex Bornet & Flahault e Microcystis (Kützing) ex Lemmermann, dentre outras. Além disso, desde 2012, tem ocorrido nestes reservatórios florações de Ceratium furcoides. Este organismo quando em extensas florações tem sido relacionado à perda da qualidade dos corpos hídricos. O reservatório Maestra foi construído entre os anos de 1965-1970 e abastece 22% da população de Caxias do Sul. Este reservatório fornece água para a ETA Celeste Gobatto, que utiliza o método convencional de tratamento da água. Este trabalho esta estruturado em três capítulos. O primeiro consiste de uma revisão bibliográfica de assuntos relavantes acerca do histórico do monitoramento da qualidade dos reservatórios no Brasil, da biologia de algas e cianobactérias, e as principais cianotixinas e acidentes devido à intoxicação no Brasil. Além disso, é feita uma breve revisão sobre o tratamento convencional da água, mostrando a importância de cada etapa para a remoção das impurezas, de acordo com os padrões de potabilidade da Portaria 2914. O segundo capítulo é manuscrito na forma de artigo científico intítulado “Composição de algas, cianobactérias e cianotoxinas no reservatório Maestra – Caxias do Sul, RS – Brasil”. Este estudo foi realizado entre janeiro de 2012 a abril de 2013. O terceiro capítulo consta de um manuscrito na forma de artigo científico, intitulado “Efeito do tratamento de água convencional na remoção de algas, cianobactérias e cianotoxinas em uma Estação de Tratamento de Água Convencional”. A eficiência de remoção foi avaliada em escala piloto, em uma Estação de Tratamento de Água de Caxias do Sul – RS a qual utiliza o método convencional de tratamento.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work reports the study of the bioaccumulation of potentially toxic elements (cadmium, lead and mercury) by marine macroalgae (Ulva lactuca, Fucus vesiculosus and Gracilaria gracilis), abundant in the coast and estuarine systems worldwide. These organisms proved to be capable of withstanding moderate multi-metallic contamination (environmentally relevant concentrations), incorporating high amounts of metal in their tissues. The high removal percentages achieved, in particular for mercury (99%), demonstrate the potential of these algae as a basis for a new biotechnological treatment of saline waters contaminated with metals (more efficient, cost-effective and environmentally friendly than conventional methods). U. lactuca was considered the most promising due to the better performance presented. The comparison between the bioaccumulation and biosorption processes suggested that in some cases the use of the living organism will have advantages over the application of biomass, due to the simplicity of the overall process, and the lower residual concentration of metal achieved in the solution (especially for Cd). The transfer and accumulation of Hg by terrestrial plants (Brassica juncea and Lolium perenne) in agricultural fields near a contaminated industrial area was also studied. Despite the low bioaccumulation factors found (<1), there were high Hg content in plants (up to 84 mg kg-1 in roots and up 6.9 mg kg-1 in shoots, dry weight). Daily intake estimates for grazing animals (cows and sheep) pointed to the potential risk to human health derived from consumption of their meat. The results highlighted the important role that plants and algae may have in protection, risk assessment and remediation of environmental systems contaminated with metals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

São apresentados os resultados do desenvolvimento das comunidades de algas perifíticas sobre substratos artificiais em duas lagoas de estabilização na Estação de Tratamento de Esgotos (ETE) do Lami, em Porto Alegre, Rio Grande do Sul, Brasil. Foram analisadas as mudanças na diversidade de espécies durante 8 semanas, entre outubro e dezembro de 2001, em três profundidades na coluna d'água, utilizando-se vários índices. O grupo de algas predominante no substrato superor nas duas lagoas foi o das diatomáceas, enquanto que nas profundidades média e inferior as cianobactérias foram as espécies mais freqüentes e abundantes, tanto na lagoa facultativa 1 como na lagoa de maturação 2 . Pelos resultados obtidos é possível que o substrato artificial de telas plástica utilizado neste experimento seja eficiente na remoção de nutrientes, tais como fósforo e nitrogênio. Pelo Índice Autotrófico verifica-se que as lagoas de estabilização são ambientes autotróficos, principalmente nos estratos superior e médio. Métodos estatísticos de análise multivariada foram realizados para descrever as relações entre espécies algais no tempo e em diferentes profundidades, bem como para encontrar afinidades específicas. Os resultados indicam espécies e grupos dominantes, substituições de espécies, mudanças na densidade e diversidade específica das comunidades perifíticas nessas lagoas. Este estudo demonstrou que o tempo para o estabelecimento de comunidades do perifiton diminui com a profundidade. Na análise das algas perifíticas foram registradas 32 táxons distribuídos em 4 divisões.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The artifi cial eutrophication is one of the biggest t h reat for the quality of aquatic ecosystems in the whole world. The expectations for the future climatic scenarios in arid and semi - arid regions are intense and frequent droughts enhancing the risk of eutrophicati on and cyanobacterial blooms. Restoration techniques of eutrophic lakes were proposed to reduce nutrient loading and improve the water quality. A successful technique used in temperate regions is the biomanipulation by benthivorous fish removal . Our hypoth esis is that the benthivorous fish removal reduces phytoplankton total biomass and change the composition of phytoplankton functional groups, improving water quality. The aim of the study was evaluate the impact of biomanipulation on phytoplankton function al groups and in the water quality. We applied the technique of biomanipulation in the artificial lake ESEC, in a semi - arid region of Brazil and analyzed the physical and chemical variables and the dynamic of phytoplankton functional groups monthly during November 2012 to August 2013. With the removal of benthivorous fish we observed a significant increase of the euphotic depth, phytoplankton richness and the recruitment of green algae (groups F and J ), indicators of good water quality. However, we did not observe significant differences on total phosphorous concentration and on phytoplankton biomass and diversity. The drought effect in the region during the study was evident , promoting a drastic reduction on water level which influenced the availability of resource and affected phytoplankton community before the biomanipulation. To evaluate the effect of severe drought on the dynamic of phytoplankton functional groups and test if the drought periods are favorable to dominance of cyanobacterial groups, we stu died two artificial neighbors lakes (ESEC and Pocinhos) in a semi - arid tropical region during May 2012 to February 2013. We observed a temporal differentiation of biotic and abiotic variables caused by drought. Both lakes presented reduction of 2 meters of water level and increase on conductivity, turbidity, nutrients concentration and a reduction on water transparency, during the severe drought. The deeper lake (Pocinhos) increased phytoplankton total biomass and presented cyanobacterial functional group d ominance (group S N ) and the shallower lake (ESEC) reduced phytoplankton total biomass and presented dominance of mixotrophic and flagellate functional groups (groups W 1 e W 2 ). Summarizing, the knowledge of the effects of benthivorous fish removal in semi - a rid tropical lakes still unknown and this study had limitations caused by the impact of drought. Thus, it is necessary a long term monitoring to investigate the real effects of biomanipulation on the functioning of the studied ecosystems. Otherwise, period s of drought could have opposite effects (increase or reduction) on total biomass and composition of phytoplankton functional groups. Drought not always leads to dominance of cyanobacterial groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eutrophication is the most common cause of water quality degradation in the world. This process occurs by excessive nutrients inputs, nitrogen and phosphorus, to the aquatic systems resulting in algal and cyanobacterial blooms. In shallow lakes these effects are pronounced due to the higher interaction of the lake with watershed, air and sediment. There are innumerous restoration techniques of eutrophied lakes with a range of successful results but there is only one case of successful lake restoration in Brazil: Paranoá Lake in Brasília city. The Brazilian semiarid region has many artificial lakes, named açudes, which are mostly eutrophic and shallow lakes. The eutrophication in these lakes is reported and the phytoplankton community is dominated by potentially toxic cyanobacteria species, mainly Cylindrospermopsis raciborskii. The aim of this thesis is to test techniques for water quality management which can be easily applied in Brazilian semiarid lakes. Results from a laboratory experiment suggest that the addition of a phosphorus sorbent clay associated with an aluminium based coagulant is an effective technique in removing soluble reactive phosphorus and reducing C. raciborskii growth rate – cyanobacteria potentially toxic dominant in reservoirs of Brazilian semiarid – but this effect is dependent on the biomass in the application moment. Results from a field experiment in mesocosm in a eutrophied lake showed that the addition of aluminium based coagulant and removal of benthivorous fish is more efficient in removing total phosphorus and chlorophyll-a from water column than the isolated application of one of the techniques. Lastly, laboratory tests showed that aluminium based coagulant exhibited good performance in removing turbidity and total phosphorus from water of six reservoirs but the efficiency was reduced by algal biomass and pH. The results of this study showed that the improvement in water quality of eutrophied reservoirs in semiarid region is possible through internal loading control by phosphorus precipitation and inactivation in sediments or inhibition of phosphorus release by benthivorous fishes, and also that these results show are additives in water quality improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eutrophication is the most common cause of water quality degradation in the world. This process occurs by excessive nutrients inputs, nitrogen and phosphorus, to the aquatic systems resulting in algal and cyanobacterial blooms. In shallow lakes these effects are pronounced due to the higher interaction of the lake with watershed, air and sediment. There are innumerous restoration techniques of eutrophied lakes with a range of successful results but there is only one case of successful lake restoration in Brazil: Paranoá Lake in Brasília city. The Brazilian semiarid region has many artificial lakes, named açudes, which are mostly eutrophic and shallow lakes. The eutrophication in these lakes is reported and the phytoplankton community is dominated by potentially toxic cyanobacteria species, mainly Cylindrospermopsis raciborskii. The aim of this thesis is to test techniques for water quality management which can be easily applied in Brazilian semiarid lakes. Results from a laboratory experiment suggest that the addition of a phosphorus sorbent clay associated with an aluminium based coagulant is an effective technique in removing soluble reactive phosphorus and reducing C. raciborskii growth rate – cyanobacteria potentially toxic dominant in reservoirs of Brazilian semiarid – but this effect is dependent on the biomass in the application moment. Results from a field experiment in mesocosm in a eutrophied lake showed that the addition of aluminium based coagulant and removal of benthivorous fish is more efficient in removing total phosphorus and chlorophyll-a from water column than the isolated application of one of the techniques. Lastly, laboratory tests showed that aluminium based coagulant exhibited good performance in removing turbidity and total phosphorus from water of six reservoirs but the efficiency was reduced by algal biomass and pH. The results of this study showed that the improvement in water quality of eutrophied reservoirs in semiarid region is possible through internal loading control by phosphorus precipitation and inactivation in sediments or inhibition of phosphorus release by benthivorous fishes, and also that these results show are additives in water quality improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Comunicação seleccionada e artigo em Livro de Actas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O afrouxamento dos parafusos protéticos é descrito na literatura como uma das complicações mais frequentes das próteses sobre implantes. Durante sua confecção, os profissionais sentem necessidade de remover várias vezes as próteses e/ou componentes protéticos, soltando e re-apertando os parafusos repetidamente. O principal objetivo deste trabalho foi avaliar a variação do torque de remoção de parafusos de fixação de pilares protéticos a implantes osteointegráveis após sucessivos ciclos de parafusamento e desparafusamento. Outro objetivo foi avaliar a influência do hexágono da base do pilar no torque de remoção dos parafusos. Para isso, foram utilizados 20 implantes de plataforma regular com hexágono externo e 20 pilares protéticos sextavados, que foram parafusados aos implantes com um parafuso de titânio, aplicando-se a este um torque de 32Ncm, por meio de um torquímetro digital. Os conjuntos implante/pilar/parafuso foram divididos em dois grupos: (1) pilares cujo hexágono da base foram removidos e (2) pilares convencionais, com hexágono na base. Cada conjunto recebeu uma restauração provisória e foi submetido a ciclagem mecânica por 15 minutos. Depois, os parafusos foram removidos, medindo-se o torque de remoção. Esta sequência foi repetida dez vezes e então o parafuso foi trocado por outro sem uso, e mais um ciclo foi realizado. Uma análise de regressão linear demonstrou nos dois grupos uma queda do torque de remoção do parafuso ao longo dos repetidos ciclos de inserção/remoção. A comparação entre os coeficientes da regressão nos dois grupos não revelou diferença entre eles. Também não houve diferença entre as médias das 5 últimas repetições e o 11 ciclo, com o parafuso novo. Concluiu-se que (1) repetidos parafusamentos e desparafusamentos promoveram a diminuição progressiva do torque de remoção dos parafusos, (2) a troca do parafuso por outro sem uso após dez ciclos de inserção/remoção não aumentou sua resistência ao afrouxamento, e (3) a remoção do hexágono da base do pilar protético não exerceu nenhum efeito sobre o torque de remoção do parafuso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi estudar a remoção de metais pesados de efluentes sintéticos aquosos através de nanofiltração, com utilização de membrana de poliamida. A membrana utilizada constituída de poliamida apresentou uma boa permeabilidade hidráulica, constatada pela linearidade de fluxo com a variação de pressão de trabalho. Os metais estudados foram cobre, cádmio, zinco, chumbo e níquel com especiação de nitrato e sulfato. O desempenho do sistema foi verificado pela variação dos parâmetros operacionais (pressão e fluxo), associados também com a variação da salinidade e da concentração do metal. Em uma etapa inicial estudou-se a remoção de metais (nitrato e sulfato) isoladamente em uma mesma concentração molar, na pressão de 10 bar, comparando-se as rejeições com e sem agente complexante (EDTA). Em uma segunda etapa, estudou-se o desempenho da membrana, com misturas dos metais (nitrato) e mistura de metais (sulfato), também com e sem agente complexante, os resultados mostraram que a presença de agente complexante melhorou a rejeição dos metais. Nestas misturas estudaram-se os efeitos das concentrações (0,001; 0,0005 e 0,0001mol/L) e das pressões (5; 7; 10 e 12,5 bar) no sistema de remoção, constatou-se que o aumento da concentração e diminuição da pressão afeta a remoção. Em uma terceira etapa, estudou-se a influência da salinidade pela mistura de dois metais de mesma especiação (sulfato), comparando a remoção na pressão de 10 bar. Os resultados atestaram uma rejeição maior que 94 % para todos metais, na pressão de 10 bar, indicando um excelente desempenho e fluxo adequado, daí viabilidade de processo para todas as concentrações testadas. A pertinência do teste se justifica pela adequação do permeado ao atendimento aos padrões ambientais de concentração de metais e confirmam a eficácia do sistema de nanofiltração na remoção de metais pesados

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantidade de resíduos gerados tem crescido rapidamente, sendo maior que a taxa de crescimento populacional, indicando um aumento na geração per capita. Este fato torna preocupante a maneira como é realizada a disposição final de resíduos e o impacto ambiental gerado com isso. Dentre os impactos está a produção de chorume, um poluente de elevada carga orgânica com altas concentrações de amônio e forte coloração, produzido pela decomposição química e microbiológica dos resíduos sólidos depositados em um aterro. Em locais de destino como aterros sanitários, este chorume é drenado para tratamento a fim de não impactar o local onde foi implantado o aterro. Porém, no Brasil, em grande parte dos casos, este tratamento não acontece, deixando o ambiente mais suscetível à contaminação. Este trabalho teve como finalidade determinar a quantidade de amônio presente em amostras de chorume do aterro de Gramacho no Rio de Janeiro, utilizando a cromatografia de íons para a sua quantificação, além de estudar a remoção de amônio por processos de adsorção em materiais como argilominerais. As amostras de chorume in natura apresentaram valores de pH em torno de 8,0 e concentrações de amônio entre 1665,0 e 2788,8 mg.L-1. Nas amostras analisadas após a destilação do chorume foram encontrados valores de pH entre 8,6 e 9,7 e concentrações de amônio de até 6362,3 mg.L-1, verificando que a maior concentração deste íon é arrastada nos primeiros 50 mL da destilação. Os testes de adsorção obtiveram um potencial de remoção de até 47 % do total de amônio. A metodologia aplicada se mostrou eficiente para determinação de amônio, uma vez que o tratamento prévio minimiza a ação de interferentes. Os baixos valores de remoção de amônio reforçam a necessidade de maior aprofundamento deste estudo, o que seria uma alternativa interessante para minimizar a ação deste poluente no meio ambiente